Model predictive control (MPC)
On a liquefaction train, one controller coordinates refrigerant composition, compressor loading, and feed gas rate against compressor and driver limits.
LNG advanced process control (APC) coordinates liquefaction trains, NGL fractionation, acid gas removal, and dehydration to maximize throughput within compressor and driver limits. Atlas Prediction Control restores and sustains APC performance inside the control systems you already run, through ambient and feed gas swings.
Request a Plant Performance ScanGas processing and LNG
| Unit | Interacting variables and limits | APC objective |
|---|---|---|
| Liquefaction trains | Refrigerant composition, compressor limits, ambient temperature, feed gas rate | Maximize LNG production within compressor and driver limits |
| NGL fractionation | Deethanizer and demethanizer pressures, reflux, product purity | Maximize liquids recovery at spec |
| Acid gas removal (amine) | Solvent circulation, regenerator duty, CO2 and H2S limits | Hold treated gas spec with minimum reboiler energy |
| Dehydration | Regeneration temperature, water dew point | Stable dew point with lower energy |
| Fuel gas and utility systems | Header pressure, demand swings | Smooth fuel supply to heaters and turbines |
On a liquefaction train, one controller coordinates refrigerant composition, compressor loading, and feed gas rate against compressor and driver limits.
A soft sensor infers NGL product composition or treated gas CO2 between analyzer readings.
Ratio and cascade control hold refrigerant composition and dehydration regeneration temperature steady.
Ambient-corrected driver power limits and compressor operating point calculations give the controller limits that move with the weather.
CLPM ranks loops by time in manual, oscillation, and valve health. Atlas Advisor™, where deployed, ties APC and historian signals to root cause.
Remote Resident™ rechecks models and limits across seasons and after feed changes.
assessment looks at how often compressor and driver limits bind across seasons, and at how far operators detune controllers during feed swings.
A Plant Performance Scan (2 to 4 hours, remote, no cost) scores the unit. A Plant Audit (2 to 4 days onsite) adds a financial estimate. You provide engineer time and recent operating data. Atlas provides the score, findings, and loss estimate.
Atlas designs and runs step tests in live operation, then builds or recalibrates the models. You provide operations access and test windows. Atlas provides test design, analysis, and models.
Atlas commissions the controller or soft sensor with your operators and validates it in live operation. You provide operator and engineering time and DCS integration support. Atlas provides tuning, validation, and handover.
Control Loop Performance Monitoring (CLPM) tracks loop and controller health against live data. A 90-day pilot on an agreed set of loops carries no fee.
Remote Resident™ keeps models, constraints, and loops aligned as conditions change.
LNG advanced process control (APC) coordinates liquefaction trains, NGL fractionation, acid gas removal, and dehydration to maximize throughput within compressor and driver limits. Atlas Prediction Control restores and sustains APC performance inside the control systems you already run, through ambient and feed gas swings.
Request a Plant Performance Scan